Model NO.: HTW-F16KB
HS Code: 84159090
Model NO.: HTW-F16KB
HS Code: 84159090

General

Water Flow Alarm High Pressure Temperature Switch(HTW-F16KB) series are designed to provide excellent performance where accuracy, reliability, and rugged construction (IP54)are required used in liquid flow lines carrying water or any fluid neither harmful to brass and prosphor bronze nor classified as a hazardous fluids.

They can be wired to close one circuit and open a second circuit when liquid flow either exceeds or drops below the adjusted flow rate.

The series are recommended for liquid pressure and temperature as mentioned below and must not be used on lines carrying liquids below 0 degree C.

These series may be used on liquids with high salt or chlorine content but is not for use in hazardous atmospheres.

They may be also used outdoors but must be protected from weather or splashing water.
All series flow switches are designed for use only as operating controls.

Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of user to add safety devices that protect against, or supervisory systems that warn of control failure.
 
 
Specifications 
 
Operating Pressure 10kgf/cm² (1MPa)
Withstand Pressure 17.5Kgf/cm² (1.75MPa)
Insulation Resistence Over 100Ω, DC500VM
Withstand Voltage AC1500V/1minute
Contact Point Life 1000K Cycle
Bellows Life 500K Cycle
Temperature of Fluid Max 100°C (212°F)
Body Size 1"(HTW-WS-25), 3/4"(HTW-WS-20),1/2"(HTW-WS-15)
Product description:

1, Type: HTW-F61KB-11C

2, Pipe connector: 1 in. 11-1/2 NPT Threads

3, Switch contact: SPDT

4, Bellow pipe / blade: phosphor bronze / stainless steel

5, Blade: detachable 1", 2", 3" blades and 6" blade ( uninstalled)

6, Liquid temperature: 0~121ºC

7, Max. Liquid pressure: 1034 KPa

8, Electrical ratings: 120VAC; 208VAC; 240VAC; 277VAC

9, Full load current (A): 16.0; 8.8; 8.0

10, Transient current (A): 96.0; 52.8; 48.0

11, Non-inductive current (A): 16.0

12, other: NEMA 1 shell

 

1~3" blades

 

 

 

Required to actuate switch (m³/h)

Pipe size(in)

1

1-1/4

1-1/2

2

2-1/2

3

4

5

6

8

Min. flow 

Flow increase R to B closes 

1.0

1.3

1.7

3.1

4.1

6.2

14.8

28.4

43.2

85.2

Flow decrease R to Y closes 

0.6

0.8

1.1

2.2

2.8

4.3

11.4

22.9

35.9

72.7

Max. flow 

Flow increase R to B closes

2.0

3.0

4.4

6.6

7.8

12.0

29.1

55.6

85.2

172.6

Flow decrease R to Y closes 

1.9

2.8

4.1

6.1

7.3

11.4

27.7

53.4

81.8

165.8

 

 

6" blade

 

Required to actuate switch(m³/h)

Pipe size(in)

4

5

6

8

Min. flow 

Flow increase R to B closes 

8.4

12.9

16.8

46.6

Flow decrease R to Y closes 

6.1

9.3

12.3

38.6

Max. flow 

Flow increase R to B closes

13.4

26.8

32.7

94.3

Flow decrease R to Y closes 

17.3

25.2

30.7

90.9




Water Flow Alarm High Pressure Temperature Switch (HTW-F16KB)
General

Water Flow Alarm High Pressure Temperature Switch(HTW-F16KB) series are designed to provide excellent performance where accuracy, reliability, and rugged construction (IP54)are required used in liquid flow lines carrying water or any fluid neither harmful to brass and prosphor bronze nor classified as a hazardous fluids.

They can be wired to close one circuit and open a second circuit when liquid flow either exceeds or drops below the adjusted flow rate.

The series are recommended for liquid pressure and temperature as mentioned below and must not be used on lines carrying liquids below 0 degree C.

These series may be used on liquids with high salt or chlorine content but is not for use in hazardous atmospheres.

They may be also used outdoors but must be protected from weather or splashing water.
All series flow switches are designed for use only as operating controls.

Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of user to add safety devices that protect against, or supervisory systems that warn of control failure.
 
 
Specifications 
 
Operating Pressure 10kgf/cm² (1MPa)
Withstand Pressure 17.5Kgf/cm² (1.75MPa)
Insulation Resistence Over 100Ω, DC500VM
Withstand Voltage AC1500V/1minute
Contact Point Life 1000K Cycle
Bellows Life 500K Cycle
Temperature of Fluid Max 100°C (212°F)
Body Size 1"(HTW-WS-25), 3/4"(HTW-WS-20),1/2"(HTW-WS-15)
Product description:

1, Type: HTW-F61KB-11C

2, Pipe connector: 1 in. 11-1/2 NPT Threads

3, Switch contact: SPDT

4, Bellow pipe / blade: phosphor bronze / stainless steel

5, Blade: detachable 1", 2", 3" blades and 6" blade ( uninstalled)

6, Liquid temperature: 0~121ºC

7, Max. Liquid pressure: 1034 KPa

8, Electrical ratings: 120VAC; 208VAC; 240VAC; 277VAC

9, Full load current (A): 16.0; 8.8; 8.0

10, Transient current (A): 96.0; 52.8; 48.0

11, Non-inductive current (A): 16.0

12, other: NEMA 1 shell

 

1~3" blades

 

 

 

Required to actuate switch (m³/h)

Pipe size(in)

1

1-1/4

1-1/2

2

2-1/2

3

4

5

6

8

Min. flow 

Flow increase R to B closes 

1.0

1.3

1.7

3.1

4.1

6.2

14.8

28.4

43.2

85.2

Flow decrease R to Y closes 

0.6

0.8

1.1

2.2

2.8

4.3

11.4

22.9

35.9

72.7

Max. flow 

Flow increase R to B closes

2.0

3.0

4.4

6.6

7.8

12.0

29.1

55.6

85.2

172.6

Flow decrease R to Y closes 

1.9

2.8

4.1

6.1

7.3

11.4

27.7

53.4

81.8

165.8

 

 

6" blade

 

Required to actuate switch(m³/h)

Pipe size(in)

4

5

6

8

Min. flow 

Flow increase R to B closes 

8.4

12.9

16.8

46.6

Flow decrease R to Y closes 

6.1

9.3

12.3

38.6

Max. flow 

Flow increase R to B closes

13.4

26.8

32.7

94.3

Flow decrease R to Y closes 

17.3

RG6

Coaxial Cable,RG6 Cable,RG6 Copper Cable